How the CircAdapt model works
The vessels and valves of CircAdapt (2015) as used in TorchCor: 4 elastic tubes, 2 peripheral beds and 6 valves around the heart. In TorchCor the 3D heart supplies the four chamber pressures; on this page a simple stand-in heart does, so the circulation can be shown on its own.
A ring of 8 compartments
4 heart chambers and 4 long elastic tubes. Valves, two venous openings and two peripheral beds connect them. The order is the same as in the code:
Red = oxygen-rich, blue = oxygen-poor. Dashed circles are the venous openings (no valve). Click any part to learn more.
Compared with the Korakianitis–Shi model
| Part | Korakianitis–Shi | CircAdapt |
|---|---|---|
| Vessels | 6 segments, linear stretch | 4 long tubes, stiffer when stretched, with wave effects |
| Small vessels | A resistance | Beds: flow ∝ drop (body), ∝ drop² (lungs) |
| Valves | Open or shut instantly | Blood has momentum; valves close gradually |
| Venous openings | — | Always open: blood can flow back into the veins |
| Heart chambers | Elastance model | 3D heart in TorchCor (stand-in here) |
One heartbeat, step by step
The circulation with the stand-in heart at 72 beats/min. Press play or drag across a plot.
Four building blocks
Tubes, beds and valves are CircAdapt. The heart is the part TorchCor replaces with its 3D model.
A tube gets stiffer as it stretches
Each tube's pressure follows its cross-section A = V / length. The more it is stretched, the faster pressure rises.
Wave effect: blood entering fast raises the pressure at the tube's entrance above its average: pentrance = p + Z · (inflow − outflow), where Z (the wave impedance) is larger for stiffer, narrower tubes.
k = stiffness (aging raises it). The aorta's pressure is the blood pressure; the wave effect adds to what the heart pushes against.Inputs: CircAdaptParameters
Every number is explicit; there is no parameter file. Defaults are TorchCor Lighting's. Click a part of the ring to see its parameters and their field names.
⚠ Fixed orders
Tubes: aorta, pulmonary artery, venae cavae, pulmonary veins. Valves: aortic, systemic venous opening, tricuspid, pulmonary, pulmonary venous opening, mitral. Chambers: LV, RV, LA, RA.
⚠ Units in the names
Lengths in mm, areas in mm², pressures in mmHg, volumes in mL. They are converted to SI inside.
⚠ Blood volume
Not a parameter: each tube starts at length × reference area (about 655 mL in all), plus the chambers' volumes.
All parameters in one table
Outputs: what CircAdapt returns
A state of 14 numbers, the pressures, and the flows. Flows use the Korakianitis–Shi names, so TorchCor can treat both models alike.
State (14)
8 volumes (mL), then 6 valve flows (mL/s).
pressures()
The 4 chamber inputs and the 4 tube pressures, plus KS aliases.
flows() · run()
10 flows in KS names. run() also returns each chamber's volume change.
Waveforms
Click to compare.
Try it
Change one part and watch the whole circulation respond. Dashed grey = defaults.
Under the hood
How it is solved
- Unknowns: 8 volumes and 6 valve flows.
- Method: Runge–Kutta (4th order) with 50 µs steps.
- Trial, then commit:
run()tries a step without changing anything;accept()keeps it. TorchCor repeats trials until heart and circulation volumes agree. - Chamber pressures are linear in time across each step.
- Units: mmHg, mL, s outside; SI inside.
✓ same numbers as the Python code
This page runs a JavaScript copy of circadapt.py. Its equations and steps matched the Python code to machine precision (better than 10⁻¹³). The stand-in heart and the beat-by-beat settling are this page's additions.
From the first beat to a steady beat
With the stand-in heart, beats repeat until each matches the last. LV volume, beat by beat:
Sources
- Arts T, et al. Adaptation to mechanical load determines shape and properties of heart and circulation: the CircAdapt model. Am J Physiol 288 (2005) H1943.
- Walmsley J, et al. Fast simulation of mechanical heterogeneity in the electrically asynchronous heart using the MultiPatch module. PLoS Comput Biol 11 (2015) e1004284 (valve law, S6).
- Augustin CM, et al. A computationally efficient physiologically comprehensive 3D–0D closed-loop model of the heart and circulation. CMAME 386 (2021) 114092, Appendix A (tubes and beds).